Backup and Restores
CTC Division Home Products Support Distributors Division Contact

Backup-Restore

 

Interact Project Manager (IPM) <----------> PowerStation Shell

  • Full functionality when using projects or project backups created with IPM.
  • Projects or project backupscreated with IPM can contain Interact version 4.X, 5.X, or 6.X application and/or run-time files.
    • Files are selected via path setting changes in IPM
  • IPM will not recognize projects or project backups created using the MachineShop Toolbar or MachineShop Shell

Interact Project Manager (IPM) <----------> MachineShop Shell

  • No functionality - IPM cannot communicate to the MachineShop Shell

MachineShop Toolbar <----------> PowerStation Shell

  • Full functionality with one exception:
    • You cannot restore a project backup created with the MachineShop Toolbar or the MachineShop Shell on a PowerStation via a floppy and the PowerStation Shell.
    • This is due to the different directory structures of project backups created with IPM versus MachineShop Toolbar or the MachineShop Shell.

MachineShop Toolbar <----------> MachineShop Shell

  • Full functionality when using projects or project backups created with either IPM, the MachineShop Toolbar, or the MachineShop Shell.
  • This includes local project restores via floppy and the MachineShop Shell

 

FAQ's

 

Question: Can I use Interact 6.02 to make changes, and download to older style PowerStations like the P31-212-AR?

Answer: You can download a version 6.0 project or restore a version 6.0 backup to this vintage of PowerStation using either IPM or the IPM compatible download in the MachineShop Toolbar. However, there is a problem when returning to the shell from Interact on these units when running Interact 6.0. Once you have downloaded the project, if you try to exit Interact and return to the shell, the shell is not displayed correctly and in inaccessible. If you wish to run Interact version 6.0 on these units, you would want to stop the boot up at the shell and then run Interact. That way, if you need to return to the shell, you can reboot the unit and it will stop at the shell. This is an issue that is being currently investigated in engineering. Until we have a resolution on this, We would recommend that these unit not be upgraded to Interact 6.0.

 Back to the Top  

 

Question:Will IPM download a MachineShop/Interact 6.0x project to the PowerStation Shell and/or make a backup of an Interact 6.0x application?

Answer: Yes to both questions. By manipulating the path settings in IPM, IPM can be used to create project backups of either Interact 5.21 or MachineShop/Interact 6.0x projects. IPM will download any project or restore any project backup to the PowerStation Shell.

 Back to the Top  

 

Question: Can I restore an IPM backup on a MachineShop Shell PowerStation?

Answer: Yes, you can restore an IPM backup using the IPM compatible download feature of the MachineShop Toolbar. Another alternative is to use the MachineShop Shell to restore the Interact 5.21 project backup via floppy directly on the unit. The MachineShop Shell will recognize and restore backups created using IPM. In addition, the PowerStation Shell will recognize and restore project backups created with the MachineShop Toolbar via floppy on the PowerStation. The bottom line is, if you are working with backups, it does not matter what you have used to create the backup, IPM or the MachineShop Toolbar, or what you are using to restore the backup, IPM, the MachineShop Toolbar, or via floppy on a PowerStation with either the MachineShop Shell or the PowerStation Shell, you will be able to restore the backup. The only thing that cannot be done with IPM is to transfer projects or project backups serially to the MachineShop Shell.

 Back to the Top  

 

Question: Can I download a 5.21 project using IPM to the MachineShop Shell?

Answer: No. IPM cannot download to the MachineShop Shell. That is why the IPM compatible download feature was included with the MachineShop Toolbar. In addition, the MachineShop Toolbar will recognize and restore project backups created with the MachineShop Toolbar or IPM.

 Back to the Top  

 

Question: Can MachineShop Shell be installed on the PWR hardware platform (PWR-xxxx-x and PWR-xxxx)?

Answer: No. This hardware is incapable of running the MachineShop Shell.

 Back to the Top  

Still have questions? E-mail us at:ctc_support@parker.com

Back to the Software Site Map


Parker Automation
Special Interest
Distributor
Corner
PSP
Login
CTC
News

[ Home | Products | Support | Buying | About Us | Contact |
| Free Evaluation Software ]

50 West TechneCenter Drive
Milford, OH 45150
Phone 513-831-2340

© Copyright 1998-2008
Parker Hannifin Corp.
All rights reserved.